Hi Paul, could it be vibration noise? It looks like no one has them in Stock and if I cant filter the pool, then it wont be usable. I then tried the pump at various speeds and it did not prime and circulate the water through the pool. Had it running today at high rpm and totally turned off after about 20 minutes. If you're researching Blue Essence, we're more than happy to help you figure out the best solution for replacing, upgrading, or repairing your system. Thank you so much for taking time to answer all our concerns. You can only compare 4 products at a time. If they are within range, replace the drive. My prior one was over 12 years old so Im feeling uncertain. The instant salinity in both polarities should be about the same (+/- about 200 ppm). Hi Mike, pumps are too hot to touch normally, running at 140 or so. I have a D.E. Hi Tiffany, in most inground pool cases, the pool pump should be powered by a breaker on the home main panel, which powers a breaker on the pool equipment pad sub-panel breaker box. When we first started both up there were no issues, however now when the heater kicks on the pump starts to make a high pitched noise. Excessive voltage or amps can cause the problem. Pump motors are not normally on a GFCI breaker, unless your pump plugs in to an outlet. Should there be some form of gasket here? Hi Ryan, just use a small flathead screwdriver and wedge it between the cover and motor, and wiggle it back and forth, in a few spots around the edge, and pull off with your other hand. Tim, all I can think of is maybe the pump is not self-priming pump? Lets see what we can do It probably just needs to dry out, but breakers that trip do need to be fully turned to Off, before they can be turned back On again. Per your article, it sounds like I need a new capacitor. Power going in, but power not coming out and therein lies the problem, which could just be a loose wire, broken wire or faulty resistor/capacitor/relay. Check the motor diagram for the voltage wiring diagram. Do you think the motor is fried as a result of no water running thru? Voltage cell is 10.7V and current is 0. Now it runs nice and quiet but still overheats and shuts off. Shut off the breaker, and timer, and check the tightness of all screws on timer and on pump motor. Use a Drain King to pressurize the pipe backwards, to remove such clogs. I never had this problem before. it runs about 30 minutes and trips the breaker. It now trips the breaker whenever i try to turn it back on. My pump is one horse power. Informacin detallada del sitio web y la empresa: cd77petanque.com Comit de seine et marne de ptanque Calling the pool builder for warranty info, too. thanks. Then restarts. News Reporter Reveals On Live TV That Shes Been Secretly Recording . I backflushed the filter and pump would loose almost all water in basket. Ive checked the voltage coming in before the breaker and after the breaker, (at the motherboard location), replaced the breaker just to be safe, but still, overheats. Should I shut down my system until I can get this fixed or is it safe for the motor to continue operation? My salt was tested today at 3000 and everything else was perfect. I have a dual flow 2 speed pump. Or a stuck skimmer weir. Hi Jeanna, most of those slide from 230 to 115, but some do have to be unplugged and replugged. Appreciate any help. If it still trips the breaker, it may have shorted out the motor windings, and is not repairable. The pump never turns off but it should pull the water through constantly. I have a new Power-Flo Matrix pump. It is only a 2-3 year old pump. Yes, that sounds like a filter problem, clogged up with algae or oily substance. . Below is a list of common issues that can arise with your Hayward pool heater. Could be overheating make sure the pump has lots of air around the motor, no piles of mulch or dirt packed around the pump. The Twelfth Edition of Business Research Methods reflects a thoughtful revision of a market standard. Before purchasing the new pump, I replaced the breaker just to be safe, but it is still throwing the new one. Cleaners Controls Filters General Pool/Spa Heat Pumps Heaters Lighting Pumps Robotic Cleaners Sanitization Step 3: Select model to register. All Products, View We used flocculant and vacuumed through the pump instead of to waste. Reset the average salt level on startup and whenever you replace your cell. "headline": "Hayward Pool Pump Troubleshooting",
Or is it coincidence that I have a bad line in the pool. What do I need to do to fix this? Then tighten the pump lid very tight. Oftentimes I reassemble the pump only to find the diffuser laying on the ground (doh!). 4. inspect capacitor, usually mounted at 9 oclock, for signs of leaking, bulging, cracking Its linked to an AutoChlor switcher and comes on twice a day but failed to switch on a couple of days ago. Not sure whats wrong. If its bulged, cracked or otherwise looks damaged, you can assume that it has failed. Separate the pump from the volute by removming the retainer clip, then remove the volute cover plate. New Assy is $500. The fuse is meant to protect the heater from 115V, as the voltage past the fuse should be like 28V, stepped down after the transformer. I have a blue essense 20,000 salt system and can find very little online. This is common maintenance for any pool Troubleshooting Your Hayward Aqua Rite System, Copyright 2020 INYOpools All rights reserved. Changed lid gasket and plugs in basket still same issue. Seems impeller is not turning, does it turn both ways or one way? Have a Hayward 1HP self priming super pump on an older pool the motor bearings are screaming. Shaft seal went out twice and I have a groove in the motor shaft now. To keep the water clear, hand feed liquid or granular chlorine daily, and brush/skim the pool daily. Slo puedes comparar 4 propiedades, cualquier nueva propiedad aadida reemplazar a la primera de la comparacin. Now there is no water running from the pool to the motor basket. Gail, good luck! Please consider. With a test meter, you check power at the motor, and it should be within 10% of 120V or 240V, whichever the motor is wired for, and if not, the power is traced back to a point where it full power is found, on the meter. If so, you may try to glue them in place with JB Weld or similar, and if that doesnt work, a new housing would be in order. If outlet is melted, youll need a replacement. it continues to cycle this way. Hi Sal, for the pump lid, it may help to close the incoming and outgoing valves, and open the filter air bleeder, to release the suction. If you have other questions, you can email me Davy, at swimmers@intheswim.com. That is the black cylinder located in the rear of the motor, at 9 oclock. Fourth, could be a clog or obstruction AFTER the pump, in the filter valve, or in the filter itself. Something about level of placement of pump in relation to the water surface. Was working fine until I backwashed and cleaned the basket by the pump. A click on the outlet you say? My pool guy went directly to saying I need a new one. Is the motor set to accept 220V, and matching what you measure at the motor terminals? Never had an issue with the other motors we have had. Then back to no pressure. Hi, if the spark/flame was where the plug meets the cord, it could be a plug problem or an outlet problem. It is a H400FDN series. Hello. If not, I would suspect voltage issues, especially with the overheating, be sure pump is wired to accept the incoming voltage (115V or 230V), and it doesnt fluctuate more than 10%, +/- . All Rights Reserved. Compare to Hayward T-Cell-15 Pump flow rates are found on pump flow rate curves. Inspect wiring for any loose or corroded connections. Im really uncertain exactly how to even look for a solution to my problem. You can check power in, on the incoming wires, and power out (with timer ON), on the outgoing wires that go to the motor. Spray some ant killer around, and replace the capacitor, but first, check all connections, maybe check incoming power (to the motor) if you have a test meter. If you get no response from your Hayward pool pump when you flip the switch, first verify the terminal board connections match the wiring diagram on the motor data plate label. Or if pump was off for some time, it can leak water, where it leaks air, when on. If I try to shut it off, nothing happens. Checked everything still doesnt work . Yes, if not grounded correctly, the GFCI will trip. If this is an ABG pool, check the skimmer hose and adapter fittings. One thing I discovered is that if I place it in super chlorinate mode today, once the pool pump shuts down for the day, the next day when it turns back on, it will be back in regular chlorinate mode even if the switch is still in super chlorinate mode. Check that the motor wiring matches input voltage, if the motor can be wired 110/220V. The latest Lifestyle | Daily Life news, tips, opinion and advice from The Sydney Morning Herald covering life and relationships, beauty, fashion, health & wellbeing We would like to show you a description here but the site wont allow us. I assumed electrical issue but when I checked the voltage at the back of the motor and it was good I am at a loss. It works fine otherwise, but the only way to stop it from heating up to 104 is by turning the power off to the heater. It is brand new. Sometimes I need to backwash and rinse before the water seems to get going enough to actually circulate, then Im able to switch to filter and it works. My pump impeller does not budge. The o-ring should be a very tight fit also, not loose in the groove of the lid. Hi Carl, check for an air leak in front of the pump on the suction manifold, or around the pump lid, or on around the threads of the fitting that screws into the pump. Hello, I have a 2 yo, dual speed Hayward Super Pump (same as the one you have pictured above). Should have the hard plastic side facing the motor and the soft rubber side facing the impeller. You have both filter pump and polaris pump on one timer? The most common cause for this is turning the valve with the pump on, or not pushing the valve handle down fully as the valve is re-positioned. Its a Hayward pump. If so, put the meter on the terminals where to cord connects inside the motor and see if there is power there. Did I mention low water level, stuck skimmer weirs, or clogged skimmer baskets? of and to in a is " for on that ) ( with was as it by be : 's are at this from you or i an he have ' not - which his will has but we they all their were can ; one also the dr myers ultrasound. If you have a power meter you can turn clock on and see if power is getting to the motor 110-120V. Could have been an outlet problem too, make sure wires or terminals arent touching anything except each other. Capacitors are cheap to replace, or you can test the capacitor Does it sound like the capacitor or could something else be the culprit? We would like to show you a description here but the site wont allow us. Hi David, impellers that have signs of wear are usually operating without a problem. We recently noticed the plug and cord are getting hot and the rubber is beginning to melt. Gauge was reading between 6 and 8 on filter container at this time. I think the problem is a nick in the face of the salt cell that the unions o-ring seals against, but I cant feel anything there so its not like a giant burr or anything. '' ''' - -- --- ---- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- ----- Click Here to View Replacement Aquarite Parts The rooms are equipped with a [] | Egypt Travel & Tourism Agency. voltage reachs the stationary switch. When I (electrician) arrived I was able to measure 38volts to ground in the water when the main pump (Hayward Tristar) is running. Suggestions? Ran it for two hours, then shut it down to move valve to backwash. Salt cells create cloudy bubbles, Ozonators too. near the end of last season it started loosing its prime on and off. Hi, make sure that the switches are not loose, the centrifugal switch on the end of the shaft and the Stationary switch at 6 oclock. I will re-check all the wiring. However, the timer does not work anymore. use a wrench on the rear of the shaft (or large flathead),to work the shaft back and forth until it spins freely. Approx. Motor was replaced then gfci breaker replaced to Hayward recommended breaker (same breaker I had first time) still tripping on every 4-5 days , 10 days inconstant times but again 99% of the time overnight. Tested the switch on and off and it works as expected. Hi COnnie, great question! Hi Andy, good question thanks Motor will start on low, but not on high. Impeller turns from inside basket. But higher pressure and no suction, that means an obstruction PAST the impeller. Hi Curt, not especially uncommon, small stress cracks on the outlet port of the pump, about 1/4 long? There should be no continuity.
I was wondering if the Hayward Cyclac Ball Value could be leaking? If the salt level is within range, go to Step 3. The air may be there on high speed too, its just not noticeable. If you are running the pump at full steam, and then shut it off, while looking very closely at these areas, you may see a quick spurt of water, which is where the air leak is originating from. Cleaners, Learn About But you could look further at the wires on the back of the terminal board, following them to the capacitor and switches problem lies where the power dies! cd77petanque.com Informacin detallada del sitio web y la empresa I checked the breakers, plumbing, control panel, plumbingjust need to know if I shud prepare myself to buy a replacement. I hadnt run my pumps in a couple of weeks. Make sure you. Hi Minglin, open up the pump lid, and remove the basket and check if anything is obstructing the impeller, like grass, gravel, seeds, etc. It runs fine but no strong circulation. If you pipes are underground, it could also be happening, if flex pipe was used and you have been using chlorine tablets in the skimmer. Pump is sitting about 3 feet below level of water in pool..maybe a bit more. Hi Michelle, If the pump and motor are too large and powerful for your filter size, it would create this situation. Is there a break in period for the unit or do I need to call the technician? Usually the capacitor (9 oclock) or the thermal overload switch (12 oclock) must be removed to gain access to the shaft, whereupon you can use an open end wrench to grasp the shaft and turn it slightly, back and forth, to break the rust free. I am getting 24VAC from top Rectifier to PCB Input, says it should be 12VAC. It has now been two days since the technician was here and the pump is still pushing de into the pool at lower RPM speed. At this point, you can shut off power at the breaker, and pop the mechanism out of the box by depressing the tabs on the top, and inspect the gears and motor directly, for any insect problems, gecko tails (seen it!) Jake, sounds like you got the filter up to speed. Does that have to be over the two spades or one? Hi, I changed my Sta Rite motor, it was 10 years old and did not start anylonger, with a brand new one. Any idea how to correct this. I used the override switch and it fired up and left it on for several hours then turned it over to auto and it worked again but has since stopped. Bearings produce a loud squealy sound. John, according to the manual, CEL is the code for Panel not receiving data from control. Getting air in basket, changed gasket with lube still have the same issue. "url": "https://intheswim.com/",
Dec 14, 2021. What is the problem. That could explain the pumping problems. Or to a light switch and then to a breaker, that would be more of a standard installation. Any thoughts? Hi Vic, pool pump motors have a thermal overload switch that will shut down the motor if temps get too hot. If not, the parts internally, some parts, need replacement. If it does make a hum or buzz sound, it could be a bad capacitor, the black cylinder at 9 oclock, in the rear of the motor. Why would the pump and Polaris stop working at the same time? The situation is either an air leak in FRONT of the pump, around the pump lid, the pipe coming into the pump, or leaky suction side valves. Specialties: Cycling, Kickboxing, This advanced blue media lasts for the life of the cartridge to inhibit the growth of bacteria on the pleated fabric that can foul and weaken a cartridge. This new one when turned on seems to start, and pump, but the breaker shuts off in probably less than a second. The most likely is an air leak, and the usual places are 1) pump lid not tight enough or not lubed, or bad o-ring, or loose drain plugs (or without thread sealant or o-ring). The stickers and labels mean it is WIRED to allow for 230. 3200 ppm is the ideal level. There should be NO elbow after the flow switch. Check if the pump will now run. Look at the diagram on the top center of the motor, which may provide some help, if not, call Hayward (908) 355-7995 (U.S.). When I turn the switch on for the pool, the breaker flips immediately. Is the GFCI test button tripped? Troubleshooting and diagnosing their problems. The blower will continue to run. Backwashing or cleaning the pump basket is the usual fix. I just purchased a new pump for my pool. Hi Tracy, the C48 number is not the pump model, but the motor number. Note: Antimicrobial properties are built in to the blue filter media to inhibit the growth of bacteria that may affect this product. If error occurs 10 times during a call for heat the control will go into lockout. Jul 8, 2018 #1 I have a blue essense 20,000 salt system and can find very little online. You might also check the the motor is not bound up, reaching in behind the basket to be sure you can spin the impeller with your fingertips. Thanks. Dont let pool pump problems drive you crazy! Then dunk them in the pool quickly after the acid, to rinse cleanly. I have a Hayward pool pump/filter, model SP3220EE. Its running now but when I turn it off it wont restart. We opened our pool a week ago and havent had a problem until today (May 23. http://www.inyopools.com/blogSHOP at our online store! Remove the 6 bolts that hold the seal plate to the pump housing